By Brands

MSR255 LCD Data Loggers - with 5 Internal Sensor Options and 4 Analog Inputs

Category: MSR Dataloggers

>> Measures Temperature, Humidity, Light, Air Pressure and Acceleration Simultaneously and Includes 4 Analog Inputs
>> LCD Display Shows up to 4 Current Values, Battery Status and Alarm Values
>> Stores up to 2 Million Total Readings on Internal Memory
>> Rechargeable Lithium Polymer Battery
>> Data from any number of loggers can be merged synchronously into a single Data Record
>> Accelerometer Range of ±15g with -20°C to 65°C Temperature Range
>> MSR PC Software Manages Settings and View, Edit, Export Data
>> External Temperature, Humidity, Light and Air Pressure Sensors Available
>> Includes CD Software and USB Cable

Multiple Measurement Parameters Available
>> Temperature
>> Humidity
>> Air Pressure (0 to 2000mbar or 0 to 14bar)
>> Acceleration
>> Light Level
External Sensors Available for Temperature, Humidity and Pressure

MSR255 LCD Data Logger Specifications

Measured Parameters >> Temperature
>> Relative Humidity (RH) with Integrated Temp
>> Pressure (ie. Altimeter, Water Level, Barometer)
>> 3-Axis Acceleration (ie. Determining Position)
>> Light (ie. Determining Position)
>> >> 4 Analog Inputs (0 to 3.0 Volts, 12-bit) - Standard
Note: Additional Ranges Available
0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V
Call 603-746-5524 to Order
Acceleration Range: ±15g @ -20°C to 65°C
Accuracy: ±0.15g @ 25°C
Resolution: 4mg
Response Time: 4mg
Measurement Rate: 1600 per second
Temperature Range: -10°C to 58°C (Internal); -55°C to 125°C (External)
Accuracy: ±0.5°C (Internal); ±2.0°C (External)
Resolution: 0.034°C
Response Time: Approximately 30 Seconds
Humidity Range: 0 to 100% RH, -20°C to 65°C
Accuracy: ±2% (10 to 85% RH, 0°C to 40°C); ±4% (85 to 95% RH, 0°C to 40°C); ±0.5°C (0°C to 65°C)
Resolution: 14 Bit
Response Time: Approximately 15 Seconds
Air Pressure Range: 0 to 2000 mbar Absolute or 0 to 14 Bar Absolute
Accuracy: ±2.5mbar (750 to 1100 mbar Absolute, 25C); ±50 mbar (1-10 bar Absolute, 25°C)
Resolution: 15 Bit
Response Time: Approximately 1/10 Second
Light Type: SFH 5712 Osram
Range: 0 to 65,000 lx
Accuracy: 100 to 65,000 lx, Max ±5% Linearity Error, Max Sensitivity at 500 nm
Resolution: 4 lx
Temperature Coefficient: 0°C to 50°C, <0.2%/K
Analog Input Number: 4 (Each Channel Configured for Separate Ranges)
Range: 0 to 3.0 Volts (Standard)**
Resolution: 12 Bits
Measurement Rate: 1/s to 12 Hours
Note: Additional Ranges Available
0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V
Call 603-746-5524 to Order
Sampling Rate 1/s to 12 Hours
Data Storage Capacity Approximately 2,000,000 Total Readings
Operating Mode Push Button Start/Stop
Storage Conditions Temperature: 5°C to 45°C
Humidity: 10 to 95% RH, non-condensing
Display 4 Row LCD Matrix Display
LEDs Blue: Recording Indicator
Red: Alarm Indicator
Yellow: Battery Charge Indicator
Power Supply Rechargeable Lithium Polymer Battery (2300mAh)
(USB Connection to PC recharges unit)
Battery Life 2-3 Months (Sampling Rate: 1 Minute)
Enclosure Anodised Aluminum Industrial Case with Top-Hat Rail Snapper (TS35)
Standard Version: Poly Carbonate, Not Encapsulated
Waterproof Version: Poly Carbonate Encapsulated
Standards Compliance RoHS/WEEE
Standard Version: IP60
Waterproof Version: IP67
Software Compatible Windows 7, Vista, XP and 2000
Dimensions 78mm x 62mm x 38mm
Weight 222 grams

 

1. Basic specification and technical data for the MSR255

1. Basic specification and technical data for the MSR255

HousingTechnical dataItem no.
Datenlogger MSR255: Robustes Multitalent mit LC-Anzeige

Standard IP 60
PC, not encapsulated

Housing: Anodised aluminium industrial case with top-hat rail snapper (TS35)
Size & weight: 78 x 62 x 38 mm, approx. 222 g
   
Memory capacity: Over 2 000 000 measurement parameters
   
Operation: Two keys for selecting functions and controlling data recording
Display: Four row LCD matrix display
LED: 3 colour LED to indicate data recording, alarm and charge condition
   
Integrated sensors: Selection of different sensors for temperature, relative humidity,
pressure, light and 3-axis acceleration/position
Measurement rate (MR): 1 /s to every 12 h (acceleration up to 3200 /s)
Storage rate (SR): 1 /s to every 12 h (acceleration up to 50 /s)
   
Power supply: Rechargeable lithium polymer battery 2300 mAh, external power supply unit
Interface: USB (Mini-B)
PC software: Free Setup, Reader, Viewer- & Online software
(Windows 2000/XP/Vista/7)
   
Operating conditions:   Temperature -20...+65 °C
Storage conditions:
  • Temperature +5...+45 °C (ideal storage condition for the battery)
  • 10...95 % relative humidity, non-condensing
   
Standards: The MSR255 complies with EU-Directives RoHS / WEEE.

255B10

 

Datenlogger MSR255: Robustes Multitalent mit LC-Anzeige

Waterproof IP 67
PC, encapsulated


255B11

 

2. Select the measurement parameters for the sensors (internal and external).

You can specify your MSR255 with up to five different sensors. Please select your desired measurement parameters here.

Measured
parameters
Working rangeAccuracyMeasurement/
storage rate
Item no.
Temperature internal: -20...+65 °C
external: -55...+125 °C
±0.5 °C (-10...+65 °C)
±2 °C (-55...+125 °C)
1/s up to one sample
every 12 h
T
Relative humidity
with integrated
temperature
0...100 % rel. humidity
-20...+65 °C
±2 % rel. humidity
(10...85 % rel. humidity, 0...+40 °C)
±4 % rel. humidity
(85...95 % rel. humidity, 0...+40 °C)
1/s up to one sample
every 12 h
H
Pressure absolute,
with integrated
temperature
0...2000 mbar absolute
-20...+65 °C
±2.5 mbar
(750...1100 mbar absolute, +25 °C)
1/s up to one sample
every 12 h
P
optional:
0...14 bar absolute
-20...+65 °C
±50 mbar
(1...10 bar absolute, +25 °C)
P2
3-axis-acceleration ±15 g ±0.15 g (+25 °C) Acceleration: 50/s (3200/s)
Attitude:
1 /s up to every 12 h
A
Light 0...65 000 lx max. sensitivity at 500 nm 1/s up to one sample
every 12 h
L

3. Do you require external sensors instead of internal ones?

Instead of the internal temperature, humidity, air pressure, 3-axis-acceleration and light sensors you may optionally select the corresponding external sensors (not pluggable) for the MSR255 datalogger.

External sensorWorking rangeCable length
0.15 m 0.40 m 1.00 m 1.60 m
Temperature -55...+125 °C Item no. FT2/015 Item no. FT2/040 Item no. FT2/100 Item no. FT2/160
Humidity 0...100 % rel. humidity Item no. FH/015 Item no. FH/040 Item no. FH/100 Item no. FH/160
Air pressure 2.0 bar Item no. FP/015 Item no. FP/040 Item no. FP/100 Item no. FP/160
14 bar Item no. FP2/015 Item no. FP2/040 Item no. FP2/100 Item no. FP2/160
3-axis-acceleration ±15 g Item no. FA/015 Item no. FA/040 Item no. FA/100 Item no. FA/160
Light 0...65 000 lx Item no. FL/015 Item no. FL/040 Item no. FL/100 Item no. FL/160

4. Do you require an additional 4 analogue inputs for connecting third-party sensors?

It is possible to expand the range of possible applications for which your MSR255 can be used by specifying four analogue inputs. These additional inputs allow external sensors for a wide range of measuring tasks to be connected. If required, these third-party sensors can be powered by the logger's internal battery. The power can be automatically turned on before measurements take place with a pre-settable lead time. This allows any necessary warm-up periods for the sensors to be taken into consideration.

Analogue inputsInputsInput configuration
Including an alarm output, multiple output
switching power supply and an input for
starting and stopping data recording.

Measurement/storage rate:
1/s to every 12 h

4 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard
4 analogue inputs
(resolution: 12 Bit)
Select the number of inputs for the
respective input configuration:

(1)   0...20 mA
(2)   4...20 mA
(3)   0...3.0 V
(4)   0.5...4.5 V / 0...5.0 V
(5)   0...10.0 V / 1.0...6.0 V
(6)   0...12.0 V
(7)   0...24.0 V

Location

Ask about this product