Sub Categories
DA-100 detects combustible or toxic gas leakage and transmits standard electric current output signal 4 ~ 20mA to be connected with various controllers such as gas leakage warning device (GMS-1000/1500/2000), PLC, DDC, or MMR for individual or integrated gas monitoring system(controller).
DA-50 detects various combustible & toxic gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. DA-50 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on. Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive. DA-50 provides RS-485 communication signal and gas leakage alarm signal by relay contact output. Besides, DA-50 has DC 4-20mA standard output which realizes max 2,500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission.
TS-60 is built-in Non contact Infrared thermometer and smoke sensor. The most of existing temperature and smoke sensors in markets can detect fire after the heat reach to temperature and smoke detector. However, TS-60 detects the fire by increased infrared amount and low concentrated smoke in early stage of the fire and enables to prevent the fire in advance.
SD-110 is a microprocessor internal 2-channel smoke detector. SD-110 is an environment-adaptive smoke detector which displays the concentration on the back light LCD by receiving the serial signals from two sensors and by processing them in the digital mode, and performs the variety of local functions in digital process mode. Also, it can ensure the effective remote control by stably outputting the analog serial signals to external control unit such as PLC/DDC. As one of big advantages of SD-110, it can be suitably applicable for various purposes by processing the sensible signals detected by ionization sensor by microprocessor stably and accurately. Because the existing smoke detectors have been mostly applied only for a fire alarm, it is general that they don’t ensure an accuracy and safety for a utility of industrial field. SD-110 is designed to ensure a sensibility and safety simultaneously by controlling the sensible ionization sensor with an industrial detector technology.
SD-50, the smoke detector with built-in micro processor, receiving signal from sensor and comparing it with preset alarming value, if it exceeds, transmits the relay output to be connected to PLC/DDC. Usually, the other smoke detectors designed only for fire alarm cannot be used for industrial use because it cannot secure enough accuracy and stability. However, SD-50 accommodating highest accurate ionization sensor and industrial detector technology, secures best accuracy and stability at the same time.
IR-Compact non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) and RS-485 communication signal output. It can measure from -60℃ to maximum 350℃ in the distance of 8:1 D:S (Distance to Spot) Emissivity is 0.10 ~ 0.99 adjustable. IR-Compact can monitor the temperature in real time in site through its infrared sensor part and signal processing module.
2IGA-100 two color(InGaAs/InGaAs) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 400 ℃ to maximum 1200℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target.
SS-100 two color(Si/Si) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 800 ℃ to maximum 2400℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target.



































