Sub Categories
Adapts Type-K thermocouple mini-connector to dual banana plug inputs Measurement range and accuracy: probe dependent Suitable for low voltage applications (below 30 V AC, 60 V DC) One year warranty
Includes two padded pockets for protection of two test tools, such as a digital multimeter and 60 Series IR thermometer and a pouch for test leads and other accessories. Durable polyester 600D case construction for long life. Compatible with Fluke 20, 70, 11X, 170 Series digital multimeters and other similar format test tools. One-year warranty.
Built in thermometer for HVAC applications Microamps to test flame sensors LoZ: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) CAT III 600 V safety rated
Wide temperature range from -30° to 650°C (–20° to 1202°F) 12:1 distance-to-spot ratio ±1% Accuracy of the reading. Dual lasers to accurately identify spot size Rugged performance Survives 9.8 foot/3 meter drops to wood floors Water and dust resistance IP54 rated to withstand rain, splashing liquids, dust and dirt Small and easy to use Ergonomic fit to "feel" good in your hand Multi-angle Backlit display
Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable
Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable
Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)