Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter

MEMORY HiCORDER MR8847 Series High-speed 20MS/s Multi-channel Memory Recorder Provides Simultaneous Data Acquisition During Field Testing with Rugged Portability and Built-in Printer Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just an oscilloscope, the MR8847 Series accommodates plug-and-play input modules to meet applications such as monitoring commercial power supplies, fault analysis of electrical equipment, testing of automotive mechanisms, and general inspection of various industrial facilities. • MR8847-01 (64MW memory, main unit only) • MR8847-02 (256MW memory, main unit only) • MR8847-03 (512MW memory, main unit only) * Main unit MR8847-01/ -02/ -03 cannot operate alone. You must install one or more optional input modules in the unit.

1-channel 4-20mA Loggers to Record Instrumentation Signals and Other low DC A Signals Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5031 instrumentation signals such as 4-20mA signals over 1 channel in as fast as 1 second intervals. Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC

Easily Transfer Logging Data from a LR5000 Series Data Logger to a PC The Hioki LR5091 is a communication adapter for transferring data from the LR5000 Series Data Loggers. Simply dock the data logger onto the Communication Adapater to transfer data using infrared, then upload the data to a PC via USB using the bundled PC application. Note: Communication Adapter LR5091 or Data Collector LR5092-20 is necessary to transfer data from a LR5000 Series Data Logger to a PC

Wirelessly Transfer Logging Data from a LR5000 Series Data Logger The Hioki LR5092-20 is a data collector for wirelessly collecting data from the LR5000 Series Data Loggers. Simply dock the Data Collector onto the data logger to transfer data using infrared, then upload the data to a PC using USB or SD card. A maximum of 60,000 data x 16 channels can be collected up to 500 times on 2 batteries. Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC

1-channel DC Voltage Loggers to Record Instrumentation Signals and Measure Analog Output from Sensors and other Devices Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR504X series logs DC voltage over 1 channel in as fast as 1 second intervals, available in three different ranges. • LR5041 (±50mV DC), • LR5042 ( ±5V DC), • LR5043 (±50V DC) Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC

2-channel Current Logger to Easily Record Load Current of 50/60Hz Lines and Leak Current Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5051 logs current over 2 channels in as fast as 1 second intervals. Customers using the previous Model 3636-20 Clamp Logger should note that the LR5051 can only record 15,000 points of average data, vs. 32,000 data points available in the 3636-20. Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC

2-channel Temperature and Humidity Logger with -40°C to 85°C range Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5001 logs temperature and humidity over 2 channels in as fast as 1 second intervals. Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC

1-channel Temperature Logger with -40°C to 180°C range Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5011 logs temperature over 1 channel in as fast as 1 second intervals. Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC