Sub Categories
Test voltages to up 10 kV CAT III 1000 V, CAT IV 600 V safety rating Warning function alert for increased user safety Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V Up to 99 memory locations Over 750 tests between battery charges Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2TΩ Timer settings up to 99 minutes
Test voltages to up 10 kV CAT III 1000 V, CAT IV 600 V safety rating Warning function alert for increased user safety Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V Up to 99 memory locations Over 750 tests between battery charges Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2TΩ Timer settings up to 99 minutes
Insulation Test Range: 0.01MΩ to 10GΩ Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V Automatic calculation of Polarization Index and Dielectric Absorption Ratio saves both time and money Compare (Pass/Fail) function makes repetitive tests simple and easy Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage: 0.1 V to 600 V 200 mA Continuity Resistance: 0.01 Ω to 20.00 K Ω Save battery power with auto Power off Read measurements easily with large, backlit display CAT IV 600 V over-voltage category rating for added user protection
Insulation Test Range: 0.1MΩ to 2000MΩ Insulation Test Voltages: 500 V, 1000 V Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage: 0.1 V to 600 V 200 mA Continuity Resistance: 0.01 Ω to 20.00 K Ω Save battery power with auto Power off Read measurements easily with large, backlit display CAT IV 600 V over-voltage category rating for added user protection
Large display with backlight Insulation test (1587: 0.01 Mohm to 2 Gohm), (1577: 0.1 Mohm to 600 Mohm) Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V), (1577: 500 V, 1000 V) Live circuit detection prevents insulation test if voltage> 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (W), Continuity Auto power off to save battery power CAT III 1000 V, CAT IV 600 V measurement category Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work Rugged, utility hard case allows you to bring everything you need for the job 3-year warranty
Improved visibility with backlit screen Ability to measure up to 100 meters (330 ft) Tripod mode allows you to mount to a tripod for measuring long distances Stake out function Reduction of estimation errors, saving both time and money Instant measurement with one-button operation Easy addition and subtraction function The most advanced laser technology for distance measurement Simple one-button operation to instantly measure distance between two objects Bright laser for easy targeting even at longer distances Quick calculation of area (square feet/meters) and volume Easy addition and subtraction function Enhanced Pythagoras calculation for determining distance indirectly from three other measurements Audible keypad feedback Inclination sensor for taking measurements in hard to reach areas Compass provides a "heading" for distance measurement Automated endpiece correction: when measuring from an edge or corner, a built-in sensor detects the position of this bracket and automatically changes the reference point Storage of the last twenty measurements for quick recall of distance Strong environmental protection with I Stores up to five measurement...
Improved visibility with backlit screen Ability to measure up to 80 m (260 ft) Tripod mode allows you to mount to a tripod for measuring long distances Stake out function Reduction of estimation errors, saving both time and money Instant measurement with one-button operation Easy addition and subtraction function The most advanced laser technology for distance measurement Simple one-button operation to instantly measure distance between two objects Bright laser for easy targeting even at longer distances Quick calculation of area (square feet/meters) and volume Easy addition and subtraction function Enhanced Pythagoras calculation for determining distance indirectly from three other measurements Audible keypad feedback Storage of the last twenty measurements for quick recall of distance Strong environmental protection with I Stores up to five measurement results Battery life of 3000 measurements with automatic shut-off feature Two-line display with display hold (until next button is pressed) Carrying pouch secures to your tool belt Powered by two AAA batteries
Reduction of estimation errors, saving both time and money Instant measurement with one-button operation Easy addition and subtraction function The most advanced laser technology for distance measurement Simple one-button operation to instantly measure distance between two objects Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in) Bright laser for easy targeting even at longer distances Quick calculation of area (square feet/meters) and volume Easy addition and subtraction function Pythagoras function indirectly measures height via two other measurements Stores up to five measurement results Battery life of 3000 measurements with automatic shut-off feature Two-line display with display hold (until next button is pressed) Carrying pouch secures to your tool belt Powered by two AAA batteries