Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter

Temperature-compensated differential pressure sensor 0 to 2000 hPa in instrument Additional 2 probe inputs for the connection of further probes for the measurement of pressure and temperature Leakage rate measurement (pressure drop per time) Direct zeroing of display value from pressure probes Display of Hold-, max. and min. values Easy data storage by measurement site as well as analysis, archiving and documentation via optional PC software Testing of pressure drop in containers, pipelines etc. Available in 2 accuracy classes: Testo 526-1: accuracy 0.1 % of final value Testo 526-2: accuracy 0.05 % of final value

Temperature-compensated differential pressure sensor in instrument Additional 2 probe inputs for connection of further Pressure and Temperature measurement probes Direct calculation of flow velocity and volume flow Direct zeroing of display value from pressure probes Display of Hold-, max. and min. values Easy data storage by measurement site as well as analysis, archiving and documentation via optional PC software Available in 2 accuracy classes: Testo 521-1: accuracy 0.2 % of final value Testo 521-2: accuracy 0.1 % of final value

8 pressure units can be selected: kPa, hPa, Pa, mm H2O, mm Hg, psi, inch H2O, inch Hg 2 flow velocity units can be selected: m/s, fpm Integrated tightness compensation Display illumination Max./min. as well as Hold-function Printout of measurement values incl. date/time and min./max. values Available in 4 different versions: 512-1WC: Measuring range 0 to 2 hPa 512-10WC: Measuring range 0 to 20 hPa 512: Measuring range 0 to 200 hPa 512-2000HPA: Measuring range 0 to 2000 hPa (without flow velocity and Pascal measurement)

Measures absolute pressure, e.g. for absolute pressure compensation in flow velocity measurements with a Pitot tube Calculation of barometric air pressure Barometric altitude measurement Accuracy +/-1.2"H20 Protective cap for safe storage Including wrist strap and belt clip Backlit display 8 switchable pressure units: hPa, mbar, Pa, mm H2O, mm Hg, in H2O, in Hg, psi

Display in Pascal optional over entire measurement range Accuracy: ±0.01 "H20 (0 to 0.12 "H20) / ±0.02 "H20 (0.13 to 0.4 "H20) Temperature compensation Magnetic back permits free-hand work Flow velocity measurement with Pitot tube (Pitot tube not included in delivery) Air density compensation Protective cap for safe storage Including wrist strap and belt clip Backlit display Switchable units: hPa, mbar, Pa mm H2O, mm Hg, in H2O, in Hg, psi, m/s, fpm

Pressure drop test set For use with pressure meters Includes manual bulb pump, hoses, T-fitting with valve, 1/2" rubber conical test stopper 200 mbar pressure

The Testo 570 RSA is ideal for servicing, maintaining and commissioning, refrigeration and heat pump systems including the newest 16 SEER systems. Built-in vacuum sensor 4-way valve block 3 Temperature probe inputs Datalogging capacity of up to 10,000 measurements Compact design, hardened housing and extremely convenient operation for ease-of-use, transport and setup Measurement of low and high pressure as well as calculation of temperatures, fast and accurate Simultaneous calculation of superheat and subcooling in real time with 2 probes 40 refrigerant profiles built in for automatic PT calculations Optional printer for on-site documentation

Four-way valve block for fast and efficient servicing Integrated vacuum measurement supports evacuation of the system Two temperature probe inputs for simultaneous real-time calculation of superheat and subcooling. The 557 will also perform leak tests on AC/R systems with temperature compensation, insuring accurate results.