Loggers

  • Filter
Category: Logger

3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage • Power Quality analysis(only on KEW 5020)(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions)   Large Capacity for storing 60,000 data points 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded   Lowpass Filter will filter out the harmonics(Cutoff Frequency = Approx. 160Hz)   LED flickers when the preset current / voltage value is exceeded   CALL: Confirmation of recorded data • The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes) • RECALL: The last 10 recorded data points including time/date can be recalled on the logger display

Category: Logger

THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel Continuous measurement time   About 40 days   Data where it doesn’t disappear even if battery is consumed   Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)   Battery residual display   The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)   The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software

Floating voltage can be measured *Floating voltage:phase to phase voltage not grounded *KEW 5020-01:KEW 5020 logger with KEW 8309 (1 pce.) For use with following model 5020

Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at the sensor part • Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315

Flexible for various test fields • Can measure AC current up to 3000A • Flexible and light weight by the air core coil used at the sensor part • Measurable conductor size:max Φ150mm • Designed to meet the international safety standardIEC 61010-1 CAT.III 600V Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315

Applicable model 5010/5020 Conductor size Φ24 Rated current AC 100A Output voltage AC 500mV/100A (AC 5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 9.5Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2 Dimensions 97(L) x 59(W) x 26(D) mm Weight Approx.150g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Applicable model 5010/5020 Conductor size Φ40 Rated current AC 500A Output voltage AC 500mV/500A (AC 1mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.9Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2 Dimensions 128(L) x 81(W) x 36(D) mm Weight Approx.260g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Applicable model 5010/5020 Conductor size Φ55 Rated current AC 1000A Output voltage AC 500mV/1000A (AC 0.5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.5Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2 Dimensions 170(L) x 105(W) x 48(D) mm Weight Approx.360g Accessories 9094 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)